1. Set temperature shutdown function:
Turn the knob of the shutdown temperature controller to set a temperature as the shutdown temperature. When the recovery is completed, the solvent vapor in the steam pipe will gradually decrease, the scale of the steam temperature gauge will gradually drop, and the shutdown system will be triggered, and the machine will automatically shut down. This function stops the machine completely and plays the role of shutting down the whole machine.
2. Timing shutdown function:
The recycling time of the machine is set in advance, and the machine will automatically stop after the machine starts up and runs for the preset time. With this function, the recovery time can be appropriately shortened to ensure that a small amount of solution is reserved in the recovery bucket to make the residue liquid when the recovery is completed, which is convenient for cleaning and can effectively prevent the occurrence of burnout or gas explosion. This timing protection system plays the role of the whole machine.
3. Ultra-high temperature protection function:
The maximum heating temperature is preset. When the temperature of the heating medium oil reaches the preset maximum temperature, the high temperature protection red light is on and the heater stops heating. This function ensures the safe operation of the machine in the set temperature range and effectively prevents the heating temperature from being too high.
4. Ultra-high voltage protection function:
If the pipeline is blocked, the steam will not be discharged through the steam pipeline, and the pressure in the barrel will rise, exceeding the external pressure by 0.38Bar, and the safety valve on the lid of the barrel will automatically open to relieve the pressure to ensure the safety of equipment and operators.
5. Power failure protection function:
If there is a sudden power failure during the operation of the machine, the machine will activate the power failure protection function and automatically shut down. When the power is supplied again, the power indicator will be on, but the machine will not run.
6. Lower slag discharge function:
The bottom discharge function, when the residue is collected and cleaned, it is not necessary to open the lid, but to open the valve to allow the residue to flow out naturally, avoiding the unpleasant smell released by the volatilized solvent when cleaning the residue, which is more different from the staff. Operation.